Lanry Instruments (Shanghai) Co., Ltd.
Contact Now

Fiberglass Pipe Ultrasonic Liquid Flow Meter Insertion Installation 4-20mA Pulse Output

Brand Name : Lanry

Model Number : TF1100-EI

Certification : CE

Place of Origin : Shanghai, China (Mainland)

MOQ : 1 Unit

Price : Negotiable

Supply Ability : 1000 Unit/Week

Packaging Details : packing: 1unit/carton

Product Name : Insertion Ultrasonic Flowmeter

Accuracy : Reading+/- 1%

High Temp : -35-150°C

Transducer type : Hot-tapped

Output : 4-20mA/pulse

Application Pipe : Fiberglass, carbon steel PVC pipe

Contact Now

Fiberglass Pipe Ultrasonic Flowmeter Insertion installation with 4-20mA pulse output

TF1100-EI transit-time Insertion ultrasonic flowmeter provides abundant capabilities for accurate liquid flow measurement from outside of a pipe. It utilizes state-of-the-art technologies on ultrasonic transmission /receiving, digital signal processing and transit-time measurement. The proprietary signal quality tracking and self-adapting technologies allow system to optimally adapt to different pipe materials automatically. Due to hot-tapped mounting of insertion transducers, there is no ultrasonic compound and coupling problem; Even though the transducers are inserted into pipe wall, they do not intrude into the flow, thus, do not generate disturbance or pressure drop to the flow. The insertion (wetted) type has the advantage of long-term stability and better accuracy.

It is ok for Fiberglass pipe application and install the sensor with Hoop, if you need more information and application picture, pls contact us.

Data sheet Download TF1100-EI transit-time insertion ultrasonic flowm...

Manual Download TF-1100-EC&EI heat meter Manual.pdf

Features:

  1. Hot-tapped installation, no pipe line flow interrupted.
  2. No moving parts, no pressure drop, no maintenance.
  3. Spool-piece transducer for best accuracy and better long-term stability.
  4. High temp. Insertion transducers are suitable for high temperature of -35℃~150℃.
  5. Wide bi-directional Flow range of 0.03 to 36 m/s, and wide range of pipe sizes from DN65 to DN6000.
  6. Data logger function.
  7. The heat measurement function by configuring with paired temperature sensors

Application:

Water and waste water industry - hot water, cooling water, potable water, sea water etc.)
Petrochemical industry
Chemical industry -chlorine, alcohol, acids, .thermal oils.etc
Refrigeration and air conditioning systems
Food , beverage and pharmaceutical industry
Power supply- nuclear power plants, thermal & hydropower plants), heat energy boiler feed water.etc
Metallurgy and mining applications
Mechanical engineering and plant engineering-pipeline leak detection, inspection, tracking and collection.

Fiberglass Pipe Ultrasonic Liquid Flow Meter Insertion Installation 4-20mA Pulse Output Fiberglass Pipe Ultrasonic Liquid Flow Meter Insertion Installation 4-20mA Pulse Output

Specifications: Transmitter

Measurement principle Ultrasonic transit-time dfference correlation principle
Flow velocity range 0.01 to 12 m/s, bi-directional
Reaolution 0.25mm/s
Repeatability 0.2% of reading
Accuracy ±1.0% of reading at rates >0.3 m/s);±0.003 m/s of reading at rates<0.3 m/s
Resonse time 0.5s
Sensitivity 0.003m/s
Damping of displayed value 0-99s(selectable by user)
Liquid Types Supported both clean and somewhat dirty liquids with turbidity <10000 ppm
Power Supply AC: 85-265V DC: 24V/500mA
Enclosure type Wall-mounted
Degree of protection IP66 according to EN60529
Operating temperature -10℃ to +60℃
Housing material Fiberglass
Display 4 line×16 English letters LCD graphic display, backlit
Units User Configured (English and Metric)
Rate Rate and Velocity Display
Totalized gallons, ft³, barrels, lbs, liters, m³,kg
Thermal energy unit GJ,KWh can be optional
Communication 4~20mA(accuracy 0.1%),OCT, Relay, RS232, RS485 (Modbus),datalogger
Security Keypad lockout, system lockout
Size 244*196*144mm
Weight 2.4kg

Specifications: Transducer

Degree of protection IP67 or IP68 according to EN60529
Suited Liquid Temperature Std. Temp.: -35℃~85℃
High Temp.: -35℃~150℃
Pipe diameter range DN65-6000
Transducer Size Type S Φ58*199mm
Material of transducer Stainless Steel
Cable Length Std: 10m
Temperature Sensor Pt1000, 0 to 200℃, Clamp-on and Insertion type Accuracy: ±0.1%


Product Tags:

insertion type ultrasonic flow meter

      

digital ultrasonic flow meter

      
Quality Fiberglass Pipe Ultrasonic Liquid Flow Meter Insertion Installation 4-20mA Pulse Output for sale

Fiberglass Pipe Ultrasonic Liquid Flow Meter Insertion Installation 4-20mA Pulse Output Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Lanry Instruments (Shanghai) Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)